Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FDU92-RG6A
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website:https://www.cwlyautomation.com
+/- 2mm + 0.17% of measured distance
Process temperature
-40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit
0.7 bar ... 4 bar abs
(10 psi ... 58 psi
Max. measurement distance
Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Main wetted parts
PVDF (fully welded IP68 / NEMA 6P)
Field of application Ultrasonic measurement Time-of-Flight Prosonic FDU92-RG6A
The FDU92 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 20m (65ft), solids 10m (33ft).
Sensor for continuous, non-contact level measurement of fluids and bulk materials in silos, on belts, stockpiles and in crushers. Also for flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.
Process connection: Thread
Temperature: -40 to +95°C (-40 to +203°F)
Pressure: +0.7 to +4bar (+10 to +58psi)
Maximum measuring range: Liquids 20m (65ft), solids 10m (33ft)
Blocking distance: 0.4m (1.3ft)
International explosion protection certificates
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website:https://www.cwlyautomation.com
Benefits Ultrasonic measurement Time-of-Flight Prosonic FDU92-RG6A
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
Hermetically welded PVDF sensor for highest chemical resistance
Suited for rough ambient conditions thanks to separate installation from the transmitter
(up to 300m)
Reduced build-up formation because of the self-cleaning effect
Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning
Weather resistant and flood-proof (IP 68)
Integrated heating against a build-up of ice at the sensor (optional) ensures reliable measurement
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website:https://www.cwlyautomation.com
More Endress + Hauser FDU92-RG6A Ultrasonic measurement Time-of-Flight Prosonic
Ultrasonic measurement Time-of-Flight Prosonic FDU92-RN2A
Ultrasonic measurement Time-of-Flight Prosonic FDU92-RN1A
Ultrasonic measurement Time-of-Flight Prosonic FDU92-RG1A
Ultrasonic measurement Time-of-Flight Prosonic FDU92-RG1A
Ultrasonic measurement Time-of-Flight Prosonic FDU92-LG1A
Ultrasonic measurement Time-of-Flight Prosonic FDU92-RG6A
Read more